Faktura

BR-DE-21

warningXRechnung 3.0.2 (Germany)profileCIIUBLBT-24

Das Element "Specification identifier" (BT-24) soll syntaktisch der Kennung des Standards XRechnung entsprechen.

Why it fails

The specification identifier (BT-24) is not an XRechnung customisation ID, so the receiver will not apply the XRechnung rule set.

How to fix it

Set BT-24 to urn:cen.eu:en16931:2017#compliant#urn:xoev-de:kosit:standard:xrechnung_3.0 (add #conformant#...:extension:xrechnung_3.0 only if you use the extension). Copy it exactly.

What the validator checks

CII — context

ram:GuidelineSpecifiedDocumentContextParameter/ram:ID = $XR-CIUS-ID or ram:GuidelineSpecifiedDocumentContextParameter/ram:ID = $XR-EXTENSION-ID or ram:GuidelineSpecifiedDocumentContextParameter/ram:ID = $XR-CVD-ID

UBL — context

cbc:CustomizationID = $XR-CIUS-ID or cbc:CustomizationID = $XR-EXTENSION-ID or cbc:CustomizationID = $XR-CVD-ID

Related rules

Part of BR-DE — XRechnung (Germany).

Validate an invoice against this rule →